TM 9-2330-238-14
5-32. STOWAGE COMPARTMENT BOX DOOR MAINTENANCE (M749) (Cont).
I c.
CLEANING AND INSPECTION I
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open frame or excessive heat.
The solvents flash point is 100°F-138°F (38°C-59°C). if you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. if solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean parts with dry cleaning solvent and dry thoroughly.
2.
Inspect tumbler case subassembly and latches for ease of operation.
3.
Inspect locking arms for cracks, bends, or breaks. Straighten any minor
4.
Inspect door for cracks, bends, dents, or tears.
bends
5.
Inspect mounting hardware for cracks or stripped threads. Replace defective parts as necessary.
d .
ASSEMBLY I
1.
Position door handle (19) in place on outer side of stowage compartment box door (5) and install three screws
(20).
2.
Install screw (21) and padlock (22) on stowage compartment box door (5).
3.
Position two latches (16) in place on inside of stowage compartment box door (5) and install eight screws (23).
4.
Position tumbler case subassembly (25) and upper and lower locking arms (15 and 24) in place on stowage
compartment box door (5) and install four screws (18), new Iockwashers (17), new Iockwashers (26), and nuts
(27).
5.
Position locking arms (15 and 24) in place on two latches (16) and install two new cotter pins (14).
6.
Position seal (9), hinge (10), seal (3), and two retainers (4) in place on stowage compartment box door (5) and
install 30 screws (7), new Iockwashers (6), and nuts (8).
I e.
INSTALLATION I
1.
Position seal (11) and stowage compartment box door (5) in place in stowage compartment box (1) and install
five screws (2), new Iockwashers (12), and nuts (13).
2.
Close and latch stowage compartment box door (5).
5-92