Figure 4-6. Hydraulic motor, removal and installation.
Figure 4-8. Elevating cylinder. removal and installation

Maintenance Manual For Auger, Earth, Skid Mounted, Type I Page Navigation
  25    26    27    28    29  30  31    32    33    34    35  
img
. . . .
b. Leveling, Cylinder.
4-22. Hydraulic Motor
(1) Inspection. Check the leveling cylinder for any
a. Inspection. Visually inspect the motor for any
cracks or leaks. Replace a damaged cylinder.
cracks in housing or other damage Replace a damaged
(2) Removal.
Remove  leveling  cylinder  as
motor.
instructed in figure 4-8.
b. Removal.  Remove the hydraulic motor as
(3) Installation. Installation is reverse of removal.
instructed in figure 4-6. Operate winch lever to align set
screw with pipe plug lever.
c. Installation.
Install the hydraulic motor by
4-24. Hydraulic Tank
reversing the procedures given for removal.
a. Breather Cap.
4-23. Hydraulic Cylinders
(1) Removal and installation. Remove the breather
a. Elevating Cylinder.
cap (1, fig. 4-9) from the top of the hydraulic reservoir
(1) Inspection. Check the elevating cylinder for any
by rotating the cap counterclockwise and removing.
Installation is opposite of removal.
cracks and leaks. Replace a damaged cylinder.
(2) Servicing.
Clean the breather cap in an
(2) Removal.
Remove elevating cylinder as
instructed in figure 4-7.
approved cleaning solvent and dry with compressed air.
(3) Installation. Installation is reverse of removal.
Inspect cap for damage. Replace a damaged cap.
DISCONNECT HYDRAULIC LINES AT THE BOTTOM
OF THE ELEVATING CYLINDER.
REMOVE  THE  UPPER  LOCKNUT  WASHERS.
PROVIDE  A  SUPPORT  TO  HOLD  THE
ELEVATING CYLINDER'; THEN REMOVE THE
CAPSCREW FROM THE CYLINDER AND THE
AUGER.
REMOVE  THE  LOCKNUT  AND
CAPSCREW AT THE BOTTOM TO REMOVE THE
ELEVATING CYLINDER.
Figure 4-7. Elevating cylinder, removal and installation
4-14