TM 5-3805-296-23-6
0438
REMOVAL CONTINUED
NOTE
Note location of O-rings to aid in installation.
6. Remove two small O-rings (Figure 5, Item 1) from ejector forward solenoid (Figure 5, Item 2). Discard o-rings.
7. Remove large O-ring (Figure 5, Item 3) from ejector forward solenoid (Figure 5, Item 2). Discard O-ring.
Figure 5. O-rings.
0438
END OF TASK
CLEANING AND INSPECTION
000438
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK