Figure 10. O-rings.
Figure 12. Tiedown Straps.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  1107    1108    1109    1110    1111  1112  1113    1114    1115    1116    1117  
img
.
TM 5-3805-296-23-6
0437
INSTALLATION CONTINUED
WARNING
Allow hydraulic system to cool before performing procedure. Hot hydraulic fluid can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills. Failure to follow this warning
may result in injury or death to personnel.
3. Install bowl down solenoid (Figure 11, Item 7), washer (Figure 11, Item 5), and bolt (Figure 11, Item 6) on rear
main control valve (Figure 11, Item 1). Do not tighten bolt at this time.
4. Install ladder clamp (Figure 11, Item 4), washer (Figure 11, Item 2), and bolt (Figure 11, Item 3) on bowl down
solenoid (Figure 11, Item 7), tighten bolts (Figure 11, Items 3 and 6).
Figure 11. Bowl Down Solenoid.
0437
0437-12