TM 5-3805-296-23-6
0435
REMOVAL CONTINUED
NOTE
Note location of O-rings to aid in installation.
12. Remove two small O-rings (Figure 9, Item 1) from ejector forward solenoid (Figure 9, Item 2). Discard O-rings.
13. Remove large O-ring (Figure 9, Item 3) from ejector forward solenoid (Figure 9, Item 2). Discard O-ring.
Figure 9. O-rings.
0435
END OF TASK
CLEANING AND INSPECTION
000435
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK
INSTALLATION
000435
NOTE
Install O-rings as noted during removal.
1. Install new large O-ring (Figure 9, Item 3) on ejector forward solenoid (Figure 9, Item 2).
2. Install two new small O-rings (Figure 9, Item 1) on ejector forward solenoid (Figure 9, Item 2).