TM 5-3805-296-23-6
0434
INSTALLATION CONTINUED
WARNING
Allow hydraulic system to cool before performing procedure. Hot hydraulic fluid can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills. Failure to follow this warning
may result in injury or death to personnel.
3. Install apron lower solenoid (Figure 9, Item 6), washer (Figure 9, Item 3), and bolt (Figure 9, Item 4) on rear
main control valve (Figure 9, Item 5). Do not tighten bolt at this time.
4. Install ladder clamp (Figure 9, Item 7), washer (Figure 9, Item 1), and bolt (Figure 9, Item 2) on apron lower
solenoid (Figure 9, Item 6), tighten bolts (Figure 9, Items 2 and 4).
Figure 9. Apron Lower Solenoid.
0434