TM 5-3805-296-23-6
0427
INSTALLATION CONTINUED
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Failure to follow this warning may result in injury or death to
personnel.
NOTE
Quick drop valve weighs 28 lb (13 kg).
5. Install new O-ring (Figure 13, Item 2) on quick drop valve (Figure 13, Item 3).
6. With assistance, install quick drop valve (Figure 13, Item 3), two washers (Figure 13, Item 1), and bolts
(Figure 13, Item 4) on machine.
Figure 13. Quick Drop Valve.
0427