• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 6. Brake Relay Connection.
Figure 8. Check Valve to Quick-Release Valve Hose.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  754    755    756    757    758  759  760    761    762    763    764  
img
.
TM 5-3805-296-23-5
0343
INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as noted during removal.
Install air hoses as tagged and marked during removal.
2. Apply sealant to air hose (Figure 7, Item 1), install air hose on fitting (Figure 7, Item 3), and tighten tube nut
(Figure 7, Item 2).
Figure 7. Air Tank Connection.
0343
0343-8


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.