Figure 75. Upper Hitch Air Tube Connection.
Figure 77. Tube Clamp.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  723    724    725    726    727  728  729    730    731    732    733  
img
.
TM 5-3805-296-23-5
0341
HITCH AIR TUBES INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air tubes and fittings.
Install air tubes as noted during removal.
Install air tubes as tagged and marked during removal.
7. Apply sealant to tube nut (Figure 76, Item 4), install air tube (Figure 76, Item 3) on fitting (Figure 76, Item 5),
and tighten tube nut.
8. Apply sealant to tube nut (Figure 76, Item 1), install air tube (Figure 76, Item 2) on fitting (Figure 76, Item 6),
and tighten tube nut.
Figure 76. Lower Hitch Air Tube Connection.
0341