TM 5-3805-296-23-5
0341
DRAFT FRAME AIR HOSES INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as noted during removal.
Install air hoses as tagged and marked during removal.
18. Apply sealant to air hose (Figure 68, Item 1), install air hose on fitting (Figure 68, Item 5), and tighten tube nut
(Figure 68, Item 6).
19. Apply sealant to air hose (Figure 68, Item 2), install air hose on fitting (Figure 68, Item 4), and tighten tube nut
(Figure 68, Item 3).
Figure 68. Forward Scraper Connector Hose Connection.
0341