Figure 55. Hydraulic Tube Clamp.
Figure 57. Forward Scraper Hose Connection.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  706    707    708    709    710  711  712    713    714    715    716  
img
.
TM 5-3805-296-23-5
0341
BOWL AIR HOSES INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
28. Install fitting (Figure 56, Item 9), washer (Figure 56, Item 8), and nut (Figure 56, Item 7) on bracket
(Figure 56, Item 11).
29. Apply sealant to fitting (Figure 56, Item 6) and install fitting on fitting (Figure 56, Item 9).
30. Apply sealant to fitting (Figure 56, Item 10) and install fitting on fitting (Figure 56, Item 9).
31. Install fitting (Figure 56, Item 2), washer (Figure 56, Item 3), and nut (Figure 56, Item 4) on bracket
(Figure 56, Item 11).
32. Apply sealant to fitting (Figure 56, Item 5) and install fitting on fitting (Figure 56, Item 2).
33. Apply sealant to fitting (Figure 56, Item 1) and install fitting on fitting (Figure 56, Item 2).
Figure 56. Scraper Hose/Connector Hose Fittings.