TM 5-3805-296-23-5
0339
REMOVAL CONTINUED
CAUTION
Plug and cap all fittings to prevent contamination. Failure to follow this caution may result
in equipment damage.
NOTE
Note position of fittings to aid in installation.
3. Remove fitting (Figure 2, Item 1) from check valve (Figure 2, Item 2).
4. Remove fitting (Figure 2, Item 4) from check valve (Figure 2, Item 2).
5. Remove check valve (Figure 2, Item 2) from fitting (Figure 2, Item 3).
Figure 2. Check Valve.
0339
END OF TASK
CLEANING AND INSPECTION
000339
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
END OF TASK