Figure 19. Drain Valve Fittings.
Figure 21. Drain Valves.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  576    577    578    579    580  581  582    583    584    585    586  
img
.
TM 5-3805-296-23-5
0335
INSTALLATION
000335
WARNING
Wheels must remain chocked during entire procedure. Failure to follow this warning may
result in injury or death to personnel.
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
1. Apply sealant to three fittings (Figure 20, Item 1), install fittings on drain valves (Figure 20, Item 2).
Figure 20. Drain Valve Fittings.
0335
0335-20