Figure 9. Supply Hose P-clamps.
Figure 11. Inboard Supply Hoses at Air Tank.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  567    568    569    570    571  572  573    574    575    576    577  
img
.
TM 5-3805-296-23-5
0335
REMOVAL CONTINUED
CAUTION
Plug and cap all air hoses and fittings to prevent contamination.
NOTE
Tag and mark air hoses to aid in installation.
24. Loosen tube nut (Figure 10, Item 2), remove air hose (Figure 10, Item 3) from fitting (Figure 10, Item 1) and
machine.
25. Loosen tube nut (Figure 10, Item 5), remove air hose (Figure 10, Item 4) from fitting (Figure 10, Item 6) and
machine.
Figure 10. Outboard Supply Hoses at Air Tank.