TM 5-3805-296-23-5
0332
REMOVAL CONTINUED
NOTE
Tag and mark air lines and hoses to aid in installation.
Tag and mark wiring harness connectors to aid in installation.
3. Loosen tube nut (Figure 2, Item 2) and remove air hose (Figure 2, Item 1) from fitting (Figure 2, Item 3).
4. Loosen tube nut (Figure 2, Item 5) and remove air hose (Figure 2, Item 6) from fitting (Figure 2, Item 4).
5. Loosen tube nut (Figure 2, Item 11) and remove air hose (Figure 2, Item 10) from fitting (Figure 2, Item 12).
6. Disconnect machine wiring harness connector (Figure 2, Item 9) from pressure sensor wiring harness
connector (Figure 2, Item 7).
7. Remove pressure sensor wiring harness connector (Figure 2, Item 7) from bracket (Figure 2, Item 8).
Figure 2. Holding Valve Connections.
0332