TM 5-3805-296-23-5
0331
INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as tagged and marked during removal.
13. Apply sealing compound to threads of air hose (Figure 15, Item 6).
14. Install air hose (Figure 15, Item 6) on fitting (Figure 15, Item 4), tighten tube nut (Figure 15, Item 5).
15. Apply sealing compound to threads of air hose (Figure 15, Item 1).
16. Install air hose (Figure 15, Item 1) on fitting (Figure 15, Item 3), tighten tube nut (Figure 15, Item 2).
Figure 15. Actuator to Quick-Release Connection.
0331