TM 5-3805-296-23-5
0331
REMOVAL CONTINUED
CAUTION
Plug and cap all air hoses and fittings to prevent contamination. Failure to follow this
caution may result in equipment damage.
NOTE
Tag and mark air hoses to aid in installation.
Note routing of air hoses to aid in installation.
21. Loosen tube nut (Figure 9, Item 2) and remove air hose (Figure 9, Item 1) from fitting (Figure 9, Item 3).
22. Loosen tube nut (Figure 9, Item 5) and remove air hose (Figure 9, Item 6) from fitting (Figure 9, Item 4).
Figure 9. Actuator to Quick-Release Connection.
0331