Figure 6. Air Brake Relay.
Figure 8. Wiring Clamp Bolts.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  492    493    494    495    496  497  498    499    500    501    502  
img
.
TM 5-3805-296-23-5
0329
INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as tagged and marked during removal.
3. Apply sealant to air hose (Figure 7, Item 11), install air hose on fitting (Figure 7, Item 10), tighten tube nut
(Figure 7, Item 12).
4. Apply sealant to air hose (Figure 7, Item 9), install air hose on fitting (Figure 7, Item 7), tighten tube nut
(Figure 7, Item 8).
5. Apply sealant to air hose (Figure 7, Item 6), install air hose on fitting (Figure 7, Item 4), tighten tube nut
(Figure 7, Item 5).
6. Apply sealant to air hose (Figure 7, Item 1), install air hose on fitting (Figure 7, Item 3), tighten tube nut
(Figure 7, Item 2).
Figure 7. Air Hoses.