TM 5-3805-296-23-5
0311
LEFT STARTER NEGATIVE CABLE REMOVAL CONTINUED
NOTE
Note cable routing to aid in installation.
Tag and mark all electrical connections to aid in installation.
3. Remove bolt (Figure 6, Item 1), washer (Figure 6, Item 2), left starter ground cable (Figure 6, Item 3), and
chassis wiring harness ground terminal (Figure 6, Item 5) from boss (Figure 6, Item 4).
4. Position chassis wiring harness ground terminal (Figure 6, Item 5) aside.
5. Remove left starter ground cable (Figure 6, Item 3) from machine.
Figure 6. Left Starter Cable at Frame.