22
TM 5-3805-296-23-5
FIELD MAINTENANCE
-
NATO SLAVE RECEPTACLE AND CABLE REPLACEMENT
0
309
NATO Slave Receptacle Removal, NATO Slave Receptacle Cable Removal, Cleaning and Inspection,
NATO Slave Receptacle Cable Installation, NATO Slave Receptacle Installation
INITIAL SETUP
Tools and Special Tools
Equipment Conditions
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-3805-296-10)
0
(WP 0550, Item 181)
Front hood opened (TM 5-3805-296-10)
0
0
Goggles, BII Item (TM 5-3805-296-10)
Right engine doors opened
0
(TM 5-3805-296-10)
0
Materials/Parts
0
Drawings Required
Rag, Wiping (WP 0549, Item 28)
0
0
Tag, Marker (WP 0549, Item 38)
RPSTL Figure 86
0
0
Lockwasher, 3B4506 (WP 0551, Item 93) (2)
0
Estimated Time to Complete
0
References
1.5 hr
0
0
TM 9-6140-200-13
0
WARNING
To avoid injury, eye protection and acid-resistant gloves must be worn when working
around batteries. DO NOT smoke, use open flame, make sparks, or create other ignition
sources around batteries. If a battery is giving off gases, it can explode and cause injury to
personnel. Remove all jewelry such as rings, ID tags, watches, and bracelets. If jewelry or
a tool contacts a battery terminal, a direct short will result in instant heating or electric
shock, damage to equipment, and injury to personnel.
Sulfuric acid contained in batteries can cause serious burns. If battery corrosion or
electrolyte makes contact with skin, eyes, or clothing, take immediate action to stop the
corrosive burning effects. Failure to follow these procedures may result in death or injury
to personnel.
EYES. Flush with cold water for no less than 15 minutes and seek medical
attention immediately.
SKIN. Flush with large amounts of cold water until all acid is removed. Seek
medical attention as required.
INTERNAL. If corrosion or electrolyte is ingested, drink large amounts of water or
milk. Follow with milk of magnesia, beaten egg, or vegetable oil. Seek medical
attention immediately.
CLOTHING/EQUIPMENT. Wash area with large amounts of cold water.
Neutralize acid with baking soda or household ammonia.
Make sure battery disconnect switch is in OFF position before replacing NATO slave
receptacle and cables.
Failure to follow this warning may result in injury or death to personnel or damage to
equipment.
0309-1