Figure 4. Hydraulic Line Fittings.
Figure 5. Lower Hydraulic Line Fittings.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  1003    1004    1005    1006    1007  1008  1009    1010    1011    1012    1013  
img
TM 5-3805-296-23-4
0280
CONTROL VALVE PILOT HOSES REMOVAL CONTINUED
CAUTION
Plug and cap all hydraulic hoses lines, and fittings to prevent contamination. Failure to
follow this caution may result in damage to equipment.
NOTE
Tag and mark hydraulic hoses to aid in installation.
Note routing and location of hydraulic hoses to aid in installation.
11. Loosen three tube nuts (Figure 5, Items 5, 6, and 7) and remove lines (Figure 5, Items 10, 11, and 12) from
lower fittings (Figure 5, Items 1, 2, and 4).
WARNING
Take the following precautions before grinding, cutting, or welding any equipment that has
been CARC-coated:
Wear protective equipment (e.g., goggles, gloves, apron) when grinding or
sanding CARC-coated equipment. Do not leave any skin exposed.
Use high-efficiency air purifying respirators when grinding or sanding CARC-coated
equipment.
Never weld or cut CARC-coated equipment; grind or sand off CARC paint
completely before welding.
CARC paint contains isocyanate (HDI) which is highly irritating to the skin and
respiratory system. High concentrations of HDI can produce itching and reddening
of the skin, a burning sensation in the throat and nose, and watering of the eyes.
In extreme concentrations, HDI can cause coughing, shortness of breath, pain
during respiration, increased sputum production, and chest tightness.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Remove CARC paint from fittings prior to removal. Failure to follow this caution will cause
damage to equipment.