TM 5-3805-296-23-4
0263
INSTALLATION CONTINUED
NOTE
Install hoses as noted during removal.
Install fitting as noted during removal.
7. Install coolant hose (Figure 16, Item 6) on two fittings (Figure 16, Items 2 and 4) with clamps
(Figure 16, Items 3 and 5).
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
8. Apply sealing compound to threads of elbow (Figure 16, Item 7).
9. Install elbow (Figure 16, Item 7) on compressor (Figure 16, Item 1).
0263