TM 5-3805-296-23-4
0262
ASSEMBLY CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
6. Apply sealing compound to threads of coolant return elbow (Figure 26, Item 3).
7. Install coolant return elbow (Figure 26, Item 3) on air compressor (Figure 26, Item 1).
8. Apply sealing compound to threads of air outlet elbow (Figure 26, Item 2).
9. Remove air outlet elbow (Figure 26, Item 2) from air compressor (Figure 26, Item 1).
Figure 26. Coolant Return Elbow and Air Compressor.
0262