TM 5-3805-296-23-4
0259
AIR CLEANER ASSEMBLY BRACKET INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
4. Apply sealing compound to fitting (Figure 14, Item 2).
5. Install fitting (Figure 14, Item 2) on air filter housing (Figure 14, Item 1).
6. Install new O-ring (Figure 14, Item 4) and turbocharger inlet pressure sensor (Figure 14, Item 3) on air cleaner
assembly (Figure 14, Item 1).
Figure 14. Turbocharger Inlet Pressure Sensor.
0259
END OF TASK