AIR CLEANER ASSEMBLY SERVICE
Figure 2. Pressure Indicator and Fitting.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  535    536    537    538    539  540  541    542    543    544    545  
img
.
TM 5-3805-296-23-4
0259
PRESSURE INDICATOR REMOVAL
000259
NOTE
Note position of fittings to aid in installation.
1. Remove hose (Figure 1, Item 5) from hose fitting (Figure 1, Item 4).
2. Remove hose fitting (Figure 1, Item 4) from fitting (Figure 1, Item 3).
3. Remove fitting (Figure 1, Item 3) from elbow (Figure 1, Item 2).
4. Remove elbow (Figure 1, Item 2) from air cleaner assembly (Figure 1, Item 1).
Figure 1. Pressure Indicator.