Figure 16. Drain Valve and Transmission Oil Cooler.
Figure 18. Drain Valve and Transmission Oil Cooler.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  527    528    529    530    531  532  533    534    535    536    537  
img
.
TM 5-3805-296-23-4
0258
LOWER RADIATOR HOSE INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
13. Apply sealing compound to threads of fitting (Figure 17, Item 2).
14. Install fitting (Figure 17, Item 2) on T-fitting (Figure 17, Item 3).
15. Install new O-ring (Figure 17, Item 1) on fitting (Figure 17, Item 2).
Figure 17. O-ring and T-fitting.
0258
0258-16