TM 5-3805-296-23-4
0239
DISASSEMBLY CONTINUED
6. Remove O-ring (Figure 9, Item 2) from adapter (Figure 9, Item 1). Discard O-ring.
NOTE
Use bolts from step 4 to perform step 7.
7. Install two bolts (Figure 9, Item 3) evenly and remove adapter (Figure 9, Item 1) and O-ring (Figure 9, Item 5)
from water pump (Figure 9, Item 4). Discard O-ring.
8. Remove two bolts (Figure 9, Item 3) from adapter (Figure 9, Item 1).
Figure 9. Elbow and Water Pump.
0239
END OF TASK
CLEANING AND INSPECTION
000239
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0539).
END OF TASK
ASSEMBLY
000239
1. Install new O-ring (Figure 9, Item 5) and adapter (Figure 9, Item 1) on water pump (Figure 9, Item 4).
2. Install new O-ring (Figure 9, Item 2) on adapter (Figure 9, Item 1).