Table 1. One or Both Stop Lights Do Not Operate, Turn Signals Operate Normally Continued.
Index

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1104    1105    1106    1107    1108  1109  1110    1111    1112    1113    1114  
img
TM 5-3805-296-23-2
0151
Table 1. One or Both Stop Lights Do Not Operate, Turn Signals Operate Normally Continued.
0151
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
One or Both Stop Lights Do
3. If removed, install lower and upper
Not Operate, Turn Signals
plenum on ROPS (WP 0504).
Operate Normally
4. Have assistant turn battery
Continued
disconnect switch to ON position
and start engine
(TM 5-3805-296-10). Allow air
supply pressure gauge to reach
normal operating pressure before
proceeding (TM 5-3805-296-10).
5. Have assistant turn mode switch
on military light switch
to SER. DRIVE position
(TM 5-3805-296-10).
6. Observe stop lights while
Both Stop Lights Operate
assistant applies brakes
Troubleshooting complete.
(TM 5-3805-296-10).
One or Both Stop Lights Do Not
Operate Repeat troubleshooting from
the beginning.