TM 5-3805-296-23-2
0132
Table 1. Heater Does Not Operate Properly Continued.
0132
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Heater Does Not Operate
Test Step 6. Test Voltage to Air
Properly Continued
Conditioner Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector W-C22
(WP 0012, Figure 271)
from connector CA-C1
(WP 0012, Figure 272).
3. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
Voltage 11.5 to 14 V Replace air
(WP 0540), test for voltage
conditioner wiring harness (WP 0527).
between connector W-C22
Proceed to Test Step 14.
terminal 10 and terminal 6
Voltage Less Than 11.5 V Replace
(WP 0012, Figure 271).
main cab wiring harness (WP 0505).
Proceed to Test Step 14.
Test Step 7. Inspect Cooling System.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Perform cooling system inspection
No Class III Leaks or Damage Found
(WP 0166) and inspect for Class III
Replace water valve (WP 0458).
leaks and damage.
Proceed to Test Step 14.
Class III Leaks or Damage Found
Repair or replace components as
required by inspection of cooling
system (WP 0166).
Proceed to Test Step 14.
Test Step 8. Test Voltage to Air
Conditioner Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector W-C22
(WP 0012, Figure 271)
from connector CA-C1
(WP 0012, Figure 272).
3. Connect jumper wire between
terminal 6 and terminal 9
of connector W-C22
(WP 0012, Figure 271).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
0132-7