Table 1. Service or Parking Brakes Do Not Release Correctly Continued.
0114
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 28. Test System Air
Service or Parking Brakes
Pressure.
Do Not Release Correctly -
Continued
NOTE
Nipple 6V-3989 and quick disconnect hose 177-7861 are from Gauge,
Pressure Kit 1U-5482.
1. Install quick disconnect coupling
half (Figure 18, Item 1) on air drain
connection (Figure 18, Item 2).
2. Connect quick disconnect hose
(Figure 18, Item 3) on quick
disconnect coupling half
(Figure 18, Item 1).
Figure 18. Air Drain Connection.
0114