Table 1. 1433 Scraper Parking Brake Solenoid Valve Diagnostic Codes Continued.
Table 1. 1433 Scraper Parking Brake Solenoid Valve Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  350    351    352    353    354  355  356    357    358    359    360  
img
.
TM 5-3805-296-23-2
0088
Table 1. 1433 Scraper Parking Brake Solenoid Valve Diagnostic Codes Continued.
088
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
1433-05 Scraper Parking
4. Using digital multimeter
Resistance 5.0 Ohms or Less
Brake Solenoid Current
(WP 0540), measure resistance
Proceed to Test Step 4.
between connector AE-C1
Below Normal Continued
Resistance Greater Than 5.0 Ohms
terminal 23 and terminal 24
Replace draft frame and bowl side
(WP 0012, Figure 144).
wiring harness (WP 0348).
Proceed to Test Step 7.
Test Step 4. Test Hitch Wiring
Harness for High Resistance or
Open.
1. Remove jumper wire from terminal
16 and terminal 17 of connector
AE-C2 (WP 0012, Figure 163).
2. Connect jumper wire between
terminal 23 and terminal 24 of
connector E-C2
(WP 0012, Figure 143).
3. Lower left frame access plate
(WP 0376).
4. Remove four bolts
(Figure 2, Item 1), washers
(Figure 2, Item 2), bushings
(Figure 2, Item 3), and splash
shield (Figure 2, Item 4) from
machine.
Figure 2. Splash Shield and Retaining Hardware.
0088
5. Disconnect connector E-C3
(WP 0012, Figure 142) from
connector J-C6
(WP 0012, Figure 141).
0088-8