Table 1. 0708 Transmission Downshift Solenoid Valve Diagnostic Codes Continued.
Table 1. 0708 Transmission Downshift Solenoid Valve Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
img
TM 5-3805-296-23-2
0067
Table 1. 0708 Transmission Downshift Solenoid Valve Diagnostic Codes Continued.
067
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Shorted
0708-06 Transmission Gear
Transmission Wiring Harness.
Actuator Down Solenoid
1. Turn ignition switch and battery
Current Above Normal
disconnect switch to OFF position
Continued
(TM 5-3805-296-10).
2. Disconnect connector A-C1
(WP 0012, Figure 106)
from connector J-C3
(WP 0012, Figure 101).
3. Using digital multimeter
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector AC-C1
Proceed to Test Step 5.
terminal 15 (WP 0012, Figure 106)
No Continuity Proceed to step 4.
and all other terminals
in connector AC-C1
(WP 0012, Figure 106).
4. Using digital multimeter
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector AC-C1
Proceed to Test Step 5.
terminal 15 (WP 0012, Figure 106)
No Continuity Proceed to Test
and ground.
Step 3.
Test Step 3. Test for Shorted Chassis
Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100)
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C3
Proceed to Test Step 5.
terminal 15 (WP 0012, Figure 101)
No Continuity Proceed to step 3.
and all other terminals
in connector J-C3
(WP 0012, Figure 101).
3. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 5.
terminal 51 (WP 0012, Figure 100)
No Continuity Proceed to step 4.
and all other terminals
in connector J-C8
(WP 0012, Figure 100).
4. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 5.
terminal 51 (WP 0012, Figure 100)
No Continuity Proceed to Test
and ground.
Step 4.
0067-8