Table 1. 0707 Transmission Upshift Solenoid Valve Diagnostic Codes Continued.
Table 1. 0707 Transmission Upshift Solenoid Valve Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  18    19    20    21    22  23  24    25    26    27    28  
img
TM 5-3805-296-23-2
0066
Table 1. 0707 Transmission Upshift Solenoid Valve Diagnostic Codes Continued.
066
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Shorted
0707-06 Transmission Gear
Transmission Wiring Harness.
Actuator Up Solenoid
1. Turn ignition switch and battery
Current Above Normal
disconnect switch to OFF position
Continued
(TM 5-3805-296-10).
2. Disconnect connector A-C1
(WP 0012, Figure 106)
from connector J-C3
(WP 0012, Figure 101).
3. Using digital multimeter
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector AC-C1
Proceed to Test Step 5.
terminal 16 (WP 0012, Figure 106)
No Continuity Proceed to step 4.
and all other terminals
in connector AC-C1
(WP 0012, Figure 106).
4. Using digital multimeter
Continuity Replace transmission
(WP 0540), test for continuity
wiring harness (WP 0266).
between connector AC-C1
Proceed to Test Step 5.
terminal 16 (WP 0012, Figure 106)
No Continuity Proceed to Test
and ground.
Step 3.
Test Step 3. Test for Shorted Chassis
Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100)
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C3
Proceed to Test Step 5.
terminal 16 (WP 0012, Figure 101)
No Continuity Proceed to step 3.
and all other terminals
in connector J-C3
(WP 0012, Figure 101).
3. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 5.
terminal 52 (WP 0012, Figure 100)
No Continuity Proceed to step 4.
and all other terminals
in connector J-C8
(WP 0012, Figure 100).
4. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 5.
terminal 52 (WP 0012, Figure 100)
No Continuity Proceed to Test
and ground.
Step 4.