Table 1. 0590 Communication Diagnostic Codes Continued.
Figure 31. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  902    903    904    905    906  907  908    909    910    911    912  
img
.
TM 5-3805-296-23-1
0061
Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 20. Verify Malfunction is
0590-12 Wrong Response
Resolved.
From Engine Control
1. Ensure all harness connectors are
Module Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
590-12 Wrong Response From
diagnostic codes (WP 0008).
Engine Control Module Becomes
Inactive Proceed to step 4.
590-12 Wrong Response From
Engine Control Module Remains
Active Repeat troubleshooting from
the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install instrument panel
(Figure 31, Item 3) with six bolts
(Figure 31, Item 4) on ROPS
(Figure 31, Item 5).
6. If removed, install right vent
(Figure 31, Item 7) with two bolts
(Figure 31, Item 6) on instrument
panel (Figure 31, Item 3).
7. If removed, install left vent
(Figure 31, Item 2) with two bolts
(Figure 31, Item 1) on instrument
panel (Figure 31, Item 3).
0061-54