Table 1. 0562 Monitoring System Diagnostic Codes Continued.
Table 1. 0562 Monitoring System Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  832    833    834    835    836  837  838    839    840    841    842  
img
. . .
TM 5-3805-296-23-1
0059
Table 1. 0562 Monitoring System Diagnostic Codes Continued.
059
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Verify Transmission/
0562-09 Caterpillar
Chassis ECM Part Number.
Monitoring System
ECM Part Number Correct Proceed
Verify transmission/chassis ECM part
Abnormal Update Rate
number is correct for machine.
to Test Step 3.
Continued
ECM Part Number Incorrect
Replace transmission/chassis ECM
(WP 0495).
Proceed to Test Step 4.
Test Step 3. Verify Transmission/
Chassis ECM Programming.
Verify transmission/chassis ECM has
ECM Software Correct Replace
the correct and most updated software
transmission/chassis ECM (WP 0495).
(WP 0011).
Proceed to Test Step 4.
ECM Software Incorrect Program
transmission/chassis ECM with correct
software (WP 0011).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
562-9 Caterpillar Monitoring System
Abnormal Update Rate Becomes
diagnostic codes (WP 0008).
Inactive Troubleshooting complete.
562-9 Caterpillar Monitoring System
Abnormal Update Rate Remains
Active Repeat troubleshooting from
the beginning.