PROTECTIVE ENTRANCE CONTROL MODULE. - Continued
PROTECTIVE ENTRANCE CONTROL MODULE. - Continued

Technical Manual For Protective Entrance Control Module
Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
. . .
TM 3-4240-302-30&P-3
LOCATION
ITEM
ACTION
REMOVAL
Housing
Pressure transducer MT1
1. Disassemble PECM (p. 2-33).
2. Remove connector plug (1) from pressure
transducer MT1 (2).
3. Remove tubing (3).
4. Remove two screws (4), washers (5), and
nuts (6).
5. Remove pressure transducer MT1 (2).
REPAIR
Nonmetallic tubing
Fabricate replacement tubing (3) (item 2, app B,
bulk material ). Cut to same length as tubing
being replaced.
INSTALLATION
1. Place pressure transducer MT1 (2) in housing
and secure with two screws (4), washers (5),
and nuts (6).
2. Install tubing (3).
3. Connect plug (1) to pressure transducer MT1.
4. Reassemble PECM (p. 2-33).
2-41