6
7
8
5
TM 9-4940-568-10
2-35
Table 2-1. Operators Level Preventive Maintenance Checks and Services (Before) (CONT).
Item
No.
Interval
Item to
Check/
Service
Procedure
Not Fully Mission
Capable If:
16
Before
Generator/
Engine Set
(f) Check for proper operation of fuel gage
(5). Check that fuel vent (6) is not clogged.
(g) Push lamp test switch (7) to check all
indicator lights (8), are working on generator.
17
Before
Grounding
Rod
Check grounding rod sections and brackets for
any loose or missing parts and hardware.
Grounding rod sections
are missing or damaged.