TM 5-3805-296-23-6
0405
ASSEMBLY
000405
NOTE
Install fittings as noted during removal.
1. Install new O-ring (Figure 14, Item 4) and fitting (Figure 14, Item 5) on leveling valve (Figure 14,
Item 2). Tighten jam nut (Figure 14, Item 3).
2. Install new O-ring (Figure 14, Item 6) and fitting (Figure 14, Item 1) on leveling valve (Figure 14, Item 2).
Tighten jam nut (Figure 14, Item 7).
NOTE
Install fittings as noted during removal.
3. Install new O-ring (Figure 15, Item 5) and fitting (Figure 15, Item 6) on leveling valve (Figure 15, Item 3).
Tighten jam nut (Figure 15, Item 2).
4. Install new O-ring (Figure 15, Item 4) and fitting (Figure 15, Item 7) on fitting (Figure 15, Item 6).
5. Install cover (Figure 15, Item 1) on fitting (Figure 15, Item 7).
Figure 15. Test Port.
0405