TM 5-3805-296-23-5
0305
INSTALLATION CONTINUED
NOTE
Install wiring harness as tagged and marked during removal.
Install P-clamp as noted during removal.
Install tiedown straps as noted during removal.
8. With assistance, position chassis wiring harness (Figure 13, Item 3) through access hole (Figure 13, Item 6).
9. Install chassis wiring harness (Figure 13, Item 3), ground cable (Figure 13, Item 14), washer
(Figure 13, Item 2), and bolt (Figure 13, Item 1) on frame (Figure 13, Item 9).
10. Install new tiedown straps (Figure 13, Item 13) on ladder clips (Figure 13, Item 12).
11. Install P-clamp (Figure 13, Item 4) on chassis wiring harness (Figure 13, Item 3).
12. Install P-clamp (Figure 13, Item 4), washer (Figure 13, Item 10), and bolt (Figure 13, Item 11) on frame
(Figure 13, Item 9).
13. Install P-clamp (Figure 13, Item 5) on chassis wiring harness (Figure 13, Item 3).
14. Install P-clamp (Figure 13, Item 5), washer (Figure 13, Item 7), and bolt (Figure 13, Item 8) on frame
(Figure 13, Item 9).
Figure 13. Chassis Wiring Harness Ground Connection.
0305