TM 5-3805-296-23-4
0272
INSTALLATION CONTINUED
NOTE
Remove plugs and caps from lines and fittings.
Install elbow as noted during removal.
5. Install new O-ring (Figure 14, Item 6), elbow (Figure 14, Item 5), and jam nut (Figure 14, Item 7) on line
(Figure 14, Item 8).
6. Install new O-ring (Figure 14, Item 4) and test fitting (Figure 14, Item 3) on elbow (Figure 14, Item 5).
7. Install dust cap (Figure 14, Item 2) on test fitting (Figure 14, Item 3).
8. Install new O-ring (Figure 14, Item 10) and test fitting (Figure 14, Item 11) on line (Figure 14, Item 9).
9. Install dust cap (Figure 14, Item 1) on test fitting (Figure 14, Item 11).
Figure 14. Test Fittings.
0272