TM 5-3805-296-23-2
0138
Table 1. One or More Park Lights Do Not Operate Continued.
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
One or More Park Lights Do
4. Remove two tiedown straps
Not Operate Continued
(Figure 2, Item 1) from wiring
harness (Figure 2, Item 3) and rear
blackout lamp housing
(Figure 2, Item 2). Discard tiedown
straps.
Figure 2. Tiedown Straps.
0138
5. Disconnect connector AH-C13
(WP 0012, Figure 188) from
connector GND (WP 0012,
Figure 183).
6. Disconnect connector AH-C4
(WP 0012, Figure 184) from
connector 21 (WP 0012,
Figure 183).
7. Turn battery disconnect switch to
ON position (TM 5-3805-296-10).
8. Turn mode switch on military light
switch to SER. DRIVE position
(TM 5-3805-296-10).
Voltage 18 to 26 V Replace left rear
(WP 0540), test for voltage
blackout lamp (WP 0352).
between connector AH-C4
Proceed to Test Step 26.
(WP 0012, Figure 184) and
Voltage Less Than 18 V Replace tail
connector AH-C13
lights/backup alarm wiring harness
(WP 0012, Figure 188).
(WP 0351).