2-19. AIRFLOW VALVE (CONT).
ACTION
ITEM
LOCATION
1. Remove nut (12) from screw (13). Remove
Protective cap
Airflow Valve
screw (13), nylon cable loop (14), washer (15),
nylon cable loop (16), and washer (17).
2. Remove nut (19) and washer (18) from
screw (20).
3. Remove screw (20) from rubber cap (21), nylon
cable loop (22), and washer (23).
4. Loosen adjusting screw (26), and remove hose
clamp (24) from rubber cap (21). Remove cap.
1. Fabricate replacement cable (22) (item 1, app
C, bulk materials). Cut new to same length as
old cable.
2. Crimp wire rope ferrules (25) on nylon cable
(22) as shown.
1. Install screw (20) in washer (23), loop of nylon
Protective cap
Airflow Valve
cable (22), hole in rubber cap (21), washer (18),
and nut (19).
2. Install hose clamp (24) in groove in rubber cap
(21). Tighten adjusting screw (26) slightly.
3. Install screw (13) in washer (17), loop of nylon
cable (16), washer (15), loop of nylon cable
(14), hole in airflow valve, and nut (12).