M10 PROTECTIVE ENTRANCE. - Continued
M10 PROTECTIVE ENTRANCE. - Continued

Technical Manual For Collective Protection Equipment, Guardrail With Accessories
Page Navigation
  75    76    77    78    79  80  81    82    83    84    85  
img
.
TM
3-4240-309-20&P
LOCATION
ITEM
ACTION
M10 Protective
Hose
Fabricate replacement hose (13) (fig E-3[A], app E).
Entrance
Remove adapters (12 and 18) from old hose, and
insert adapters in new hose.
Protective entrance
1.
Install hose on protective entrance control
module. Hold female hose adapter (19) with a
c o n t r o l module
wrench, and tighten male hose adapter (18).
Position protective entrance control module
2.
(17) against brackets (20) in protective
entrance.
Install screws (15) through washers (16) and
3.
into brackets (20).
Install female hose adapter (12) on coupling
4.
(14).
Install electrical cable connectors J21 (9) and
5.
J20 (8) with preformed packings (10 and 11) in
protective entrance from the inside.
From the outside, install loop of connector
6.
cover (7) and nut (5) on cable connector J21
(9). From the outside, install loop of connector
cover (6) and nut (4) on cable connector J20
(8). Tighten nut securely.
7.
Reconnect electrical cable plugs P20 (2) and
P21 (3).
2-71