TM 9-6230-210-13&P
Table 2-1. Operator Preventive Maintenance Checks and Services - continued
Item
No.
LOCATION
Item to
Interval
Procedure
Not Fully Mission
Check/Service
Capable if:
6
Before
Fuel tank, lines
Inspect for damage, proper fuel level, or
Fuel tank damaged or
and connectors
fuel leakage.
empty. Lines or connectors
have Class III leaks.
7
Before
Leveling jacks
Inspect for damage and proper operation.
Jack fails to raise or fewer
floodlight set.
8
Before
Ground rod
Inspect for damaged threads, missing or
Sections have damaged
broken sections, missing ground or or
threads. Sections are bro-
cable damp.
ken or missing. Ground
cable or damp is loose or
missing.
9
During
Fuel tank, lines,
Inspect for damage, proper fuel level, or
Fuel tank damaged or
and connectors
fuel leakage.
empty. Lines or connectors
have Class III leakge.
10
Weekly
Battery
Inspect for damage, secure mounting,
Water level is low. Termi-
corrosion, loose terminals, end proper
nals are loose or corroded.
water level.
Battery hold down is broken,
loose, or missing.
2-6