TM 9-6230-210-13&P
1.11 EQUIPMENT DATA.
Refer to Table 1-1 for Floodlight Set equipment data.
Table 1-1. Equipmnt Data for Floodlight Set, Model HLT-3K-5K-MIL.
Manufacturer
High-Lite Corporation
.
Model
HLT-3K-5K-MIL
Overall Dimensions-Towing Position
Length
145-inches (368.3 cm)
Height
78-inches (198.1 cm)
Width
61-inches (1549 cm)
Overall Dimensions-Tower Removed:
Length
107-inches (271.7 cm)
Height
50-inches (127.0 cm)
Width
61-inches (154.9 cm)
Height with mast extended.
37-feet, 9.5-inches (138.3 m)
Width with outriggers extended
109-inches (approximately) (276.86 cm)
Power Requirement
3kW, 120V, 60Hz input is required
Weight-dry (less generator set)
1653-lbs. (750.5 kg)
Weight-shipping (less generator set, tower, and
1275-lbs (578.9 kg)
floodlights
Weight with generator set and full fuel tank
2025-lbs. (919.3 kg)
Shipping displacement
390-cu.ft. (10.9 cu m)
Floodlights:
Watts
1000 ea.
Lumen output
100,000 ea.
Weight
40-lbs. ea. (18.2 kg)
Fuel tank capacity
12.87-gal. (48.7 liters)
Fuel
Gasoline, MILG-3506
SECTION III. PRINCIPLES OF OPERATION
1.12 PRINCIPLES OF OPERATION.
a. The floodlight set operates from the 120-volt, single-phase terminals on the engine-generator set. For operation
with a 3-kW generator set, the floodlight set is connected to terminals L1 and L2 of the generator output terminal board
or generator panel (GP). The black wire and green wire in the main power cable (cable from the control panel to the
generator panel) are connected to one terminal, and the white wire is connected to the other terminal.
b. Activation of CB1, 15-amp (A) single pole single throw (SPST) circuit beaker, applies power to the duplex
receptacle and battery trickle charger. The charger applies the 12-volt operating power to the RED WARNING LIGHT
TOGGLE SWITCH (S) and battery. Toggle Switch (S) applies power to the RED WARNING LIGHT (RWL).
1-6