TM 9-4940-568-34
FRS HYDRAULIC SCHEMATIC
PUMP
FILTER
QUICK
DISCONNECT
QUICK
DISCONNECT
QUICK
DISCONNECT
NOTE:
VERIFY HYDRAULIC PRESSURE SETTINGS
UNDER THE FOLLOWING CONDITIONS:
1. LOADSENSE PUMP STANDBY PRESSURE: 325 PSI ( PSI)
2. LOADSENSE PUMP LIMITING PRESSURE: 3500 PSI (0 PSI)
3. HYDRAULIC OIL TEMPERATURE: 140 (PSI)
MAIN RETURN LINE
LOAD SENSE LINE
TO PUMP
MAIN SUPPLY LINE
3000 PSI MAX SYSTEM
12.0 GPM MAX FLOW
FIGURE FO-3. HYDRAULIC SYSTEM SCHEMATIC
FOLDOUT 17 OF 19
FP 33 /FP 34 BLANK