TM 9-4940-568-20
2-136
Table 2-21. Crane Troubleshooting (CONT).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. HOIST DOES NOT RAISE WITH REMOTE CONTROL.
NOTE
Before performing crane troubleshooting procedures, make sure the FRS electrical
supply system is functioning properly.
Unless advised otherwise, the FRS 24V MASTER switch and the crane MAIN
POWER switch must be in the ON position for all voltage checks.
Test 1.
Are the boom up and down, and telescope out functions also not working using
remote control?
If none of the above listed functions operate, go to Test 2.
If boom up/down and telescope out function properly, go to Test 3.
Test 2.
Are the boom up and down, and telescope out functions also not working using
manual control?
If none of the above listed functions operate, faulty overload shutdown system,
Notify Supervisor.
If boom up/down and telescope out function properly, faulty lockout solenoid valve,
Notify Supervisor.
Test 3.
Loosen screw and remove connector from hoist UP solenoid. Place EMERGENCY
STOP switch to ON position. Hold remote control unit hoist controller in UP position
and check for 24 volts between solenoid connector, terminal 1, and known good
ground.
If 24 volts are not present, go to Test 4.
If 24 volts are present, turn MAIN POWER switch OFF and go to Test 10.
Test 4.
Disconnect the remote control cable from the remote control unit and remote control
hook-up connector on crane sub-frame. Check the cable for continuity between the
two cable ends, terminal F.
If no continuity is found on terminal F, replace the remote control cable.
If continuity is found, go to Test 5.