TM 9-2330-359-14&PTable 4-2. Organizational Troubleshootlng (Con’t).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONStep 2.Check for worn trunnion bushing.Replace trunnion bushing (para 4-45).Step 3.Check for loose or defective radius rods.Tighten or replace radius rods (para 4-54).LANDING GEAR10. LANDING GEAR DIFFICULT TO RAISE OR LOWER.Step 1.Check for misalined or damaged landing leg.Replace landing leg as required (para 4-52).Step 2.Check for damaged gearbox.Replace landing leg as required (para 4-52).SUSPENSION SYSTEM11. SEMITRAILER PULLS TO ONE SIDE.Step 1.Check for proper service brake adjustment.Adjust service brakes (para 4-31).Step 2.Check for proper wheel bearing adjustment.Adjust wheel bearings (para 4-44).Step 3.Check for loose or defective radius rods.Tighten or replace radius rods (para 4-54).12. SEMITRAILER LEANS TO ONE SIDE.Check for broken or weak spring leaves.Notify direct support maintenance if replacement is required.Change 2 4-11