TM 9-2330-359-14&P
LUBRICATION CHART
SEMITRAILER, FLATBED, BREAKBULK/CONTAINER
TRANSPORTER: 34 TON, M872 SERIES
Intervals (on-condition or hard time) and related
man-hour times are based on normal operation. The
man-hour time specified is the time you need to do all
services prescribed for a particular interval. De-
crease the intervals if your lubricants are contami-
nated, or if you are operating equipment under
adverse conditions, including longer-than-usual op-
erating hours. The intervals may be extended during
periods of low activity. If extended, adequate preser-
vation precautions must be taken.
Dotted leader lines indicate lubrication is required on
both sides of the equipment.
WARNING
Dry cleaning solvent, P-D-680, is toxic and
flammable. Always wear protective
goggles and gloves, and use only in a well-
ventilated area. Avoid contact with skin,
eyes, and clothes, and DO NOT breathe va-
pors. DO NOT use near open flame or ex-
cessive heat. The solvents flash point is
100°F-138°F (38°C-59°C). If you be-
come dizzy while using cleaning solvent,
immediately get fresh air and medical help.
If solvent contacts eyes, immediately wash
your eyes and get medical aid.
Clean all fittings and area around lubrication points
with dry cleaning solvent (Item 12, Appendix E) or
equivalent before lubricating equipment. After lubri-
cation, wipe off excess oil or grease to prevent accu-
mulation of foreign matter.
The lowest level of maintenance authorized to lubri-
cate a point is indicated in parentheses by use of the
following: (C) Operator/Crew, or (O) Unit Mainte-
nance.
3-2