TM 9-2330-359-14&P
Section Il. OPERATOR/CREW PREVENTIVE MAINTENANCE
CHECKS AND SERVICES (PMCS)
Page
Paragraph Title
Number
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2
General PMCS Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2
Leakage Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Operator/Crew Preventive Maintenance Checks and Services (PMCS), Table 2-1 . . . . . . . . . . . . . . . . . . . . . 2-4
Reporting Repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2
Service Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Specific PMCS Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3
2 - 3 . G E N E R A L.
a. To ensure that the M872 Series Flatbed Semitrailers are ready for operation at all times, they must be
inspected on a regular basis so that defects may be found before they result unserious damage, equipment failure, or
injury to personnel. This section contains systematic instructions on inspections, adjustments, and corrections to be
performed by the operator/crew.
b. While performing PMCS, read and follow all safety instructions found in the Warning Summary at the front
of this manual. Keep in mind all WARNINGs and CAUTIONs.
2-4. SERVICE INTERVALS.
Perform PMCS, found in Table 2-1, at the following intervals:
(1) Perform Before (B) PMCS just before operating the semitrailer.
(2) Perform During (D) PMCS while operating the semitrailer.
(3) Perform After (A) PMCS tight after operating the semitrailer.
(4) Perform Weekly (W) PMCS once each week.
(5) Perform Monthly (M) PMCS once each month.
2-5. REPORTING REPAIRS.
All defects which the operator cannot fix must be reported on a DA Form 2404, Equipment Inspection and
Maintenance Worksheet, immediately after completing PMCS. If a serious problem is found, IMMEDIATELY report it to
your supervisor.
2-6. GENERAL PMCS PROCEDURES.
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvents flash point is 100°F-138°F (38°C-59°C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, Immediately wash your eyes and get medical aid.
a. Keep equipment clean. Dirt, oil, and debris may cover up a serious problem. Clean as you work and as
needed. Use dry cleaning solvent (Item 6, Appendix E) on all metal surfaces. Use soap (Item 5, Appendix E) and water
on rubber, plastic, and painted surfaces.
2-2